XX112-36-00 Rev 909 Kollector Hybrid Network Digital Video Recorder Configuring the ViconNet System • 75
Configuring/Modifying Sensors (Detectors)
The ViconNet system enables you to configure or modify up to 16 sensors (4 for Kollector Strike), if
required. Each sensor that you configure in the system must be associated to a specific alarm type.
To configure/modify a sensor (detector):
1. Perform steps 1 to 3 in Configuring/Modifying Local Cameras, page 68.
2. Select a sensor button from the Detector section of the Devices List area. The Detector Settings
area at the bottom of the window displays all the configurable settings for the selected device.
3. In addition, a numerical index number is displayed automatically in the ID field. The ID number is
assigned by the system and cannot be changed (read-only).
4. In the Name field, enter a logical name for the sensor. For example, you can assign a name that relates
to the associated alarm type.
5. (Optional) In the Description field, enter descriptive textual information about the sensor.
6. To configure/modify additional sensors, repeat steps 1 to 4, as required.
As you select another button in the Device Settings window, the new or modified name of the sensor
that you have just configured is displayed automatically on the appropriate button in the Detector
section and the configuration is automatically saved.
7. Click
. The new or modified sensor configuration is saved automatically in the system (without
requiring a reboot) and the sensor appears in the Site List in the ViconNet Main window as an
available device, meaning it is available immediately for all operations.
NOTE: After you have configured a device in the system, it also appears in all other device lists, such as
when defining alarm setup links. Refer to the relevant sections in this chapter for additional details.
Komentáře k této Příručce